PRODUCT DETAILS


Features:
High efficiency, high reliability, low cost
AC input range selected by switch
100% full load burn-in test
Protections: Short circuit / Over load
Fixed switching frequency at 25KHz
Cooling by free air convection
2 year warranty


35W Single Output Switching Power Supply MS-35 series
Low price and high reliability
105ºC output capacitor
AC input power suitable for the world
Hight efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size,light weight
100% full-load burning test
Installed with EMI filter, minimum wave

SPECIFICATIONS

OUTPUT

 

Model

MS-35-5

MS-35-12

MS-35-24

DC Voltage

5V

12V

24V

Rated Current

3A

1.3A

0.7A

Current Range

0-3A

0-1.3A

0-0.7A

Rated Power

15W

15.6W

16.8W

Ripple & Noise

50mVp-p

50mVp-p

100mVp-p

Voltage Adj. Range

+10,-5%

±10%

±10%

Voltage Tolerance

±2%

±1%

±1%

Inlet Stability

±0.5%

±0.5%

±0.5%

Load Stability

±1%

±0.5%

±0.5%

Setup, Rise, Hold Up Time

200s,100ms,30ms at full load

 

 

INPUT

 

Voltage Range

100~240VAC 47-63Hz; 240~370VDC

AC Current

0.5A/115V 0.25A/230V

Efficiency

65%

68%

72%

Inrush Current

Cold-start current 15A/115V 30A/230V

Leakage Current

<0&period;5mA&sol;240VAC

 

 

PROTECTION

 

Over Load

105&percnt;~150&percnt;

Protection type&colon; Fold back current limiting Reset&colon; auto recovery

 

 

ENVIRONMENT

 

Working Temp&period;&comma; Humidity

-10ºC~&plus;60ºC&lpar;Refer to output derating curve&rpar;&comma; 20&percnt;~90&percnt;RH

Storage Temp&period;&comma; Humidity

-20ºC~&plus;85ºC&comma;10&percnt;~95&percnt;RH

Temp&period; Coefficient

±0&period;02&percnt;&sol;ºC&lpar;0~50&percnt;&rpar;

Vibration

10~500Hz&comma;2G 10min&comma;&sol;1cycle&comma;Period for 60min&comma;each axes

 

 

SAFETY

 

Withstand Voltage

I&sol;P-O&sol;P&colon; 1&period;5KVAC I&sol;P-FG&colon; 1&period;5KVAC O&sol;P-FG&colon; 0&period;5KVAC

Isolation Resistance

I&sol;P-O&sol;P&comma; I&sol;P-FG&comma; O&sol;P-FG&colon; 100M Ohms&sol;500VDC

 

 

STANDARD

 

Safety Standard

Meet UL1012 requirement&lpar;Not apply for the mark&rpar;

EMC Standard

Meet FCC PART15 J Conduction class B

 

 

OTHERS

 

Dimension

85&ast;58&ast;38mm&lpar;L&ast;W&ast;H&rpar;

Weight

0&period;4Kg

 

 

NOTE

 

1&period;The testing condition for the parameter above is&colon; 230VAC input&comma; rated load&comma; 25ºC 70&percnt; RH&period;Humidity&period;
2&period;Error&period;include the setting error&comma;line stability and load stability&period;
3&period;Wave test&colon;adopting "A12"double wire for 20MHz&comma;and 0&period;1UF&47UF capacitor short-circuit for interrupting&period;
4&period;Inlet voltage stability test&colon;when is over load&comma;the lowest voltage of inlet is up to the highest voltage&period;
5&period;Load stability test&colon;the load is from 0&percnt; to 100&percnt;&period;